RV Digital Thermostat Installation / Duo

This is the the absoule Easiest System for Self Installers! We help you every step of the way! You will NOT void the warranty by installing the furnace yourself! Every furnace comes with a complete detailed manual with lots of pictures and diagrams! If you have any technical questions or need any help whatsoever, please call Installing an outdoor wood furnace can be broken down simply. The parts needed will cost you virtually nothing: Pour a 4″ thick concrete pad to support the furnace because our smallest furnace weighs almost lb empty and about lb over a TON filled with water! You can also use SOLID concrete blocks or railroad ties – anything that will be stable and support the furnace. Dig a trench, ONLY if using insulated ducts designed for underground AND is water-tight, mold and mildew resistant – making sure it’s below the frost line, to prevent excessive heat loss. The “frost lione” is the maximum depth to which frost will penetrate the ground during the worst of winter.

Guide to Thermostat Wiring Color Code: making install simple and fast

Index Home About Blog From: John De Armond Subject: Adding wall thermostat to roof air Date: Fri, 23 Jun

I recently had a furnace come in- complaint was that nothing happened- no fan, no heat.. nothing. Whenever I have a furnace problem, the first step I take is to go to the thermostat.

Please read ALL of these instructions carefully before beginning installation. Save them for future reference. This thermostat is protected against normal minor static electric discharges, however to minimize the risk of damaging the unit in extremely dry weather, touch a grounded metal object before touching your thermostat. On new installations, follow the guidelines listed below. Locate the thermostat on an inside wall, about 5 ft. Do not locate where air circulation is poor, such as in a corner or an alcove, or behind an open door.

Do not install it where there are unusual heating conditions, such as: Do not locate in unusual cooling conditions, such as: Do not locate in a damp area.

Thermostat install help needed

Someone with more control knowledge might help you if you want it all on one thermostat and it will have to be the correct model for doing that. The boiler is set at 74 and the gas is set at 70 or something. If the wiring and control is totaly escaping you you might want to invest in a furnace man for a few hours but you need to be able to tell him exactly what you want done which is simply switch the fan on high speed and off with a thermostat for the boiler heat and the gas furance and control gets left alone.

If you have a normal 4 wire thermostat hookup with R, W, G and W terminals then it would be hard to burn the transformer up because you are dealing with only one hot wire the Red (R) and there is not a common wire to short the thermostat out.

Common in the South and warm, humid areas, a heat pump and furnace system is one of the many options for a matched system. What does a heat pump do? It simply uses electricity to move heat from one place to another. A heat pump is an energy efficient way to cool your home in the summer and heat it in the winter. To deliver the highest system efficiency, performance and climate control, an indoor cooling coil must be matched in size and rated with your heat pump.

Use a Trane coil with your Trane system for optimum reliability. What does a furnace do? Trane furnaces are uniquely designed to provide maximum heat with minimum fuel usage. And they think for themselves. Key furnace control functions are integrated into one microelectronic system that monitors the thermostat and gas valve, ensuring precise temperature control. Add to your home comfort system An air cleaner is an integral part of a home comfort system, filtering dust and pollutants out of the air you breathe, and keeping your rugs and home furnishings cleaner.

Find out how to Install a Hyprotherm Outdoor Wood Burning Furnace

You can never be too careful when it comes to this point. Even after all these years I occasionally still get shocked. Keep in mind that a many breaker panels are mislabeled.

Seriously though, I thought about the shoddy control over our natural gas furnace we have with our current, circa s Honeywell round thermostat. Sometimes I have little revelations that pop into my head and recently one of these had to do with thermostats.

What you will learn in Thermostat Wiring Colors Code article: What thermostat wire color is likely to go to which terminal on the thermostat. Basic electrical safety and standards for wiring color The function of each wire terminal on the average thermostat. Additionally highlighting some of the differences in those functions from manufacturer to manufacturer. Wire is available here. Always turn the power off!

You can do this at the air handler and condenser. Always make sure there is no voltage at the transformer before proceeding. The thermostat wire colors below are the most likely colors used for most installations. However, your thermostat wire colors may be different than what is indicated here. There is no official standard for thermostat wire colors. You can consider this the standard wiring colors for thermostat and HVAC equipment. Standards for thermostat wiring colors do not exist except for here and a few other references on the internet.

However, these are the most common wiring methods used.

Matched Systems

A lot of campers come with an old fashioned analog thermostat like the one pictured here. The problem with them is the temperature range before they cycle on or off. Features we all like to have Like many others before us, we decided to swap out our analog thermostat for a nice digital one. Many digital thermostats that will run on batteries will work as a suitable replacement. We decided on a simple, inexpensive model

To ensure that you are able to hook your specific heating product to your thermostat, you must first make sure they are compatible. For product specific information regarding how to connect your thermostat to your pellet stove, check your product manual.

The old WeatherTron was also really ugly. Having two heat sources, the electric heat pump and the furnace, seemed to complicate the setup and install of the new Thermostat. Since it took a lot research and verifying to find where all the wires from the old unit hooked into the new one, I thought it may be helpful to post the wire translation that worked for me.

Since this is a DIY project, and I have absolutely no authority on this subject, here’s a disclaimer: Really, I have very little knowledge of these systems and following the information here could cause great harm to your system. I consider myself lucky that I didn’t blow up my entire heating and cooling system or burn the house down. I did do a lot of research and in the end, ended up deductively determining the new wiring based on all the information I could find.

To this day, I’m still not sure if it’s really correct, but so far, it seems to be working with my equipment. Also, this isn’t a trial and error situation. I have no idea what happens if the power is turned on with the incorrect wiring, but I assume everything would get destroyed. Also, be careful with the old WeatherTron thermostat since it contains a mercury switch. Mercury is highly toxic and you don’t ever want to be in contact with it.

Guide to Thermostat Wiring Color Code: making install simple and fast

Quick Reply I’m trying to wire up a honeywell programmable thermostat. The existing thermostat is a 24V 2-wire system. It works fine, I just want to be able to program the thermostat.

Can I hook up a thermostat to my pellet appliance? Where should I place the thermostat? The answer to this question is dependent on the specific pellet stove model you have in your home.

You will need to obtain replacement thermostats before you begin. Are you sure that the thermostat is bad? Before you conclude that they need to be replaced you should test them. See the article ‘ Testing Water Heater Thermostats ‘ for more information on how to conduct a test. A common problem that may seem like the thermostat is a bad heating element. Not quite sure what your problem is?

Thermostat wiring for the oil furnace